Luz de Emergência Fluorescente

1. Q1 must be installed on a heat sink.
2. A 240V to 10V transformer will work better then the one in the parts list. The problem is that they are hard to find.
3. This circuit can give a nasty (but not too dangerous) shock. Be careful around the output leads.


Relação de componentes
C1_________________100uf 25V Electrolytic Capacitor
C2,C3______________0.01uf 25V Ceramic Disc Capacitor
C4_________________0.01uf 1KV Ceramic Disc Capacitor
R1_________________1K 1/4W Resistor
R2_________________2.7K 1/4W Resistor
Q1_________________IRF510 MOSFET
U1_________________TLC555 Timer IC
T1_________________6V 300mA Transformer
LAMP_______________4W Fluorescent Lamp
MISC_______________Board, Wire, Heatsink For Q1